CG170-20B Gas Generator Set
Videos not available for this product.
360 View not available for this product.
SPECIFICATION SUMMARY
- Maximum Continuous Rating 2300 ekW @1.0pf
- Fuel Type Natural Gas, Biogas, Coal Gas
- Maximum Electrical Efficiency 45.00%
- Maximum Standby Rating 2300
PRICE (USD)
Call 440-838-7348 for rate information
Generator Set Specifications
-
Maximum Continuous Rating2300 ekW @1.0pf
-
Fuel TypeNatural Gas, Biogas, Coal Gas
-
Maximum Electrical Efficiency45.00%
-
Maximum Standby Rating2300
-
Frequency50 Hz
-
RPM1500 rpm
Engine Specifications
-
Engine ModelCG170B-20
-
AspirationTA
-
Bore6.7 in
-
Stroke7.7 in
Generator Set Dimensions
-
Length258 in
-
Width67 in
-
Height89 in
-
Dry Weight - Genset47377 lb
High Efficiency, Lower Operating Costs
- Up to 45% electrical efficiency with Natural Gas
- 43.6% electrical efficiency with biogas
- Electrical output up to 2,300 kWel
- Reduced vibration and stress on components
Compact Size, High Profitability
- Compact design that delivers up to 15% more power output at the same size as its predecessor
- Long maintenance intervals (up to 80,000 hours)
- Available in different applications, such as natural gas, biogas, wellhead- and propane gas operation
- Maximum flexibility through different engine variants
Optimized Lubrication Consumption
- Consumes ~0.15g/kWh<li>
- Reduced lube oil temperature through better cooling performance<li>
- Savings of up to 3,000 liters of lube oil per year compared to comparable gensets<li>
Standard Equipment:
-
- Air Inlet
-
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
-
- Control Panels
-
- TPEM (Total Plant & Energy Management System)
-
- Cooling
-
- Jacket water and SCAC thermostats
- flange connections for JW inlet and outlet
- ANSI/DN customer flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
-
- Exhaust
-
- PEARL/Low resistence exhaust system
- Exhaust waste gate for the CG170B-20
- Closed crankcase ventilation system
-
- Fuel System
-
- Pre-chamber spark plugs
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
-
- Generator
-
- Busbar connections
- Winding temperature detectors
- grid code generator
- Reactive droop
- 3-phase sensing and KVAR/PF control
- Anti-condensation space heater
- closed-coupled generator result in no torque transmission to the base frame
-
- Starting/charging
-
- 24V starting motors
- Battery disconnect switch
-
- General
-
- Crankshaft vibration damper and guard
Optional Equipment:
-
- Cooling
-
- CHP skid