C4.4 Generator Set
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Videos not available for this product.
360 View not available for this product.
SPECIFICATION SUMMARY
PRICE (USD)
Call 440-838-7348 for rate information
Engine Specifications
-
Bore4.13 in
-
Displacement268.5 in
-
Stroke5 in
-
Fuel SystemElectronic (adjustable)
-
Engine ModelC4.4, In-line 4, 4-cycle diesel
-
Compression Ratio18.2:1
-
Governor TypeAdem™A4
-
Fuel SystemElectronic (adjustable)
-
Bore4.13 in
-
Displacement268.5 in
-
Stroke5 in
-
Fuel System5 in
-
AspirationTurbocharged
Generator Set Specifications
-
Minimum Rating36 ekW
-
Maximum Rating100 ekW
-
Voltage220 to 480 Volts
-
Frequency60 Hz
-
Speed1800 rpm
-
Emissions/Fuel StrategyNon Regulated, EU Stage II
-
Duty CycleStandby, Prime
Generator Set Dimensions
-
Height - Maximum53.6 in
-
Length - Maximum75.8 in
-
Width - Maximum44.1 in
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
R-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment:
-
- Air Inlet System
-
- Air cleaner; light duty with disposable element
-
- Air Inlet
-
- Air Cleaner
-
- Cooling
-
- Package mounted radiator
-
- Cooling System
-
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
- Radiator and cooling fan with guards
-
- Control Panel
-
- EMCP 4 Genset Controller
- EMCP 4.1
-
- Exhaust
-
- Exhaust flange outlet
-
- Exhaust System
-
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel
-
- Secondary fuel filter
- Primary fuel filter with integral water separator
- Fuel priming pump
-
- Fuel System
-
- Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
-
- Generator
-
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Voltage regulator (single phase sensing)
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- 12 leads
- IP23 protection
-
- Governing System
-
- Mechanical and electrical governing system - model dependent
-
- Power Termination
-
- Bus Bar
-
- Lube System
-
- Oil drain line with valve
- Lubricating oil
-
- Mounting System
-
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
-
- Mounting
-
- Rubber vibration isolators
-
- Starting/charging System
-
- 24V battery with rack and cables
-
- General
-
- Paint - Caterpillar Yellow except rails and radiators gloss black
- Engine and alternator pre-paint, Caterpillar yellow
-
- Starting/charging
-
- Batteries
- 24 volt starting motor
Optional Equipment:
-
- Exhaust
-
- Industrial, Residential, Critical Mufflers
-
- Generator
-
- Oversize and premium generators
- Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
- Anti-condensation heater
-
- Alternator System
-
- 3 phase sensing
- Permanent magnet
- Quadrature droop kit
- LC frame alternator with coastal insulation protection
- Anti-condensation heater
- R frame auxilliary winding
- LC frame alternator
-
- Circuit Breakers
-
- Circuit Breaker Upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
-
- Power Termination
-
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
-
- Control Panels
-
- Remote monitoring software
- Local & remote annunciator modules
- EMCP (4.2) (4.3) (4.4)
- Digital I/O module
- Load share module
-
- Cooling System
-
- Coolant heater
- Low coolant level shutdown
- Low coolant temp alarm
-
- Control Panel Options
-
- Earth fault (2 wire only)
- Panel mounted audible alarm
- Control panel heater
- Overload shutdown via breaker
- Earth leakage (2 wire only)
- Emergency stop with key
- Battery charger
- Volt free contacts
- Voltage adjust potentiometer
- Speed adjust potentiometer
- EMCP 4.2
-
- Starting/charging
-
- Charging alternator
- Oversize batteries
- Jacket water heater
- Battery chargers
- Heavy-duty starting system
-
- Enclosures
-
- Sound attenuated Level 2 enclosure
- Rental pack - CAE rental option only
- Sound attenuated Level 1 (galv)
-
- European Certifications
-
- Upgrade to STD set for CE
-
- Fuel System
-
- Low fuel level shutdown
- Low fuel level alarm
- Compact skidbase for open set
- Bunded fuel tank
- Skidbase for CALG enclosure sets
- Open set narrow base
- High fuel level alarm
-
- General
-
- CSA Certification
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Single or dual wall sub-base fuel tanks
- Single or dual wall integral fuel tanks
- Narrow, Wide or Skid Base
- EEC Declaration of Conformity
- EU Certificate of Conformance (CE)
- Automatic transfer switches (ATS)
- Integral & sub-base fuel tanks
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- UL 2200 package
-
- Global Certifications
-
- Certification for CIS
-
- Mounting Options
-
- Industrial silencer
- Battery removal
- Electronic governor
- External single point lift - enclosure
- Silencer installation kit
-
- Special Packing/inspectons For Shipment
-
- PGS test report @ 0.8 power factor
- PGS test report @ 1.0 power factor
-
- General - Accessories / Miscellaneous
-
- Packing case - compact set
- Stone guards / rad trans flange
- Packing case - canopied set