SPECIFICATION SUMMARY
  • Bore 5.4 in
  • Displacement 1649.47 in³
  • Stroke 6 in
  • Aspiration TA

PRICE (USD)
Call 440-838-7348 for rate information

Engine Specifications

  • Bore
    5.4 in
  • Displacement
    1649.47 in³
  • Stroke
    6 in
  • Aspiration
    TA
  • Fuel System
    MEUI
  • Engine Model
    C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel
  • Compression Ratio
    16.0:1
  • Governor Type
    Adem™A4
  • Aspiration
    TA
  • Fuel System
    MEUI
  • Bore
    5.4 in
  • Displacement
    1649.47 in³
  • Stroke
    6 in
  • Fuel System
    6 in

Generator Set Specifications

  • Minimum Rating
    725 ekW
  • Maximum Rating
    800 ekW
  • Voltage
    208 to 600
  • Frequency
    60 Hz
  • Speed
    1800 RPM
  • Emissions/Fuel Strategy
    EPA Tier 4 Interim

Design Criteria

Generator

EMCP Control Panel

World Wide Product Support

UL 2200 / CSA - Optional

Single-Source Supplier

Standard Equipment:

  • Air Inlet
    • Single element canister type with service indicator
  • Control Panel
    • EMCP 4 / EMCP 4.2B Genset Controllers
    • EMCP 4.2B Control Features
    • Communications
    • Programmable Protective Relaying Functions
    • Warning/shutdown Indicators
    • Digital Indicators
  • Cooling
    • Fan and belt guards drive
    • Coolant level sensor
    • Caterpillar Extended Life Coolant
    • Radiator sized to 50 degrees C (122 degrees F)
    • Coolant drain line with valve terminated on edge of base
    • ATAAC
  • Exhaust
    • Exhaust Manifold - dry
    • 203mm (8in) ID round flanged outlet
  • Fuel
    • Primary fuel filter with water separator
    • Fuel cooler
    • Flexible fuel lines - installed
    • Electric fuel priming pump
    • Secondary fuel filters
  • Generator And Attachments
    • SR5 Permanent Magnet (PM)
    • For Low BSFC configurations:
    • Integrated Voltage Regulator (IVR) includes
    • Bus bar connections:
  • Lube System
    • Integral lube oil cooler
    • Standard volume oil pan - 68 Ltr
    • Lubricating oil
    • Oil filter, filler and dipstick
    • Gear type lube oil pump
    • Oil drain lines and valve
    • Fumes disposal - open crankcase ventilation routed to front of package
  • Mounting System
    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts - shipped loose
  • Starting And Charging System
    • 24-volt electric starting motor
    • Charging Alternator 45A
    • Battery, rack and cables - shipped-loose
    • Battery disconnect switch
  • General
    • Flywheel and flywheel housing-SAE No. 0 and SAE No. 18
    • SAE Standard Rotation
    • RH Service
    • Paint: Caterpillar Yellow with high gloss black rails & radiator

Optional Equipment:

  • Air Inlet System
    • Standard air cleaners
    • Dual element air cleaners
    • Heavy duty air cleaners
  • Battery / Charging System
    • 10 Amp battery chargers
    • 20 Amp enclosure battery chargers
    • 24 Volt battery sets - Dry
    • 24 Volt electric start motors - Heavy duty
    • Jacket water heaters
    • Air starting motor with control and silencer
    • Space heater
  • Circuit Breakers
    • 400, 800, 1200, 1600, 2000, 2500, 3000 Amp, 3 pole, UL-100% rated circuit breakers
    • 2000 Amp, 3 pole, IEC rated circuit breakers
    • 800 Amp, 4 pole, IEC rated circuit breakers
  • Control Panels
    • EMCP (4.2B) (4.3) (4.4)
    • Remote mounting harness
    • Remote mounted circuit breaker terminals
    • Remote mounted panel harness mounting kit
    • Auxiliary box options
    • Side extension box
    • Cable shroud - Top mounted
    • Cable shroud - Bottom mounted
    • Cat connect telematics
    • Installed DIO module
    • Remote DIO module
    • Annunciator modules
    • Remote annunciator modules
    • Modbus monitor local packages
    • Load share module
    • Vandal proof panel cover
  • Cooling System
    • Standard radiator
    • High ambient radiator
    • Certified radiator
    • Extended life coolant
    • Radiator duct flange
  • Enclosures
    • Special sound attenuated enclosure
    • Enclosure with lifting base or fuel tank
    • Enclosure fuel tank options
    • Enclosure louvers
    • Cold weather bundle
    • Enclosure lighting
    • AC distribution panel, lights and outlet
    • Panel bracket
    • Enclosure colors
  • Exhaust
    • Flanges
    • Guard and shield system
    • Elbows
    • Flexible fittings
    • Mufflers
    • Exhaust through the wall kit
  • Generator And Attachments
    • 60 Hz standard generators
    • 60 Hz premium generators
  • Lube System
    • Oil level regulator
    • Prelube pumps
  • Mounting System
    • Puck style low efficiency isolators
    • Spring-type vibration isolator
    • IBC vibration isolators
    • Mounting base type
  • Power Connections
    • Neutral grounding connection
    • Center post busbar
    • Power connections - Right / Left / Rear
    • Cable entry - Right / Left / Rear
  • Starting/charging
    • Battery chargers
    • Oversize batteries
    • Jacket water heater
    • Heavy-duty starting system
    • Charging alternator
    • Air starting motor with control and silencer
  • Special Tests / Reports
    • IBC Seismic certifications
    • OSHPD Seismic certifications
    • Special CSA test cerification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report
    • Standard engine test
    • Torsional vibration analysis report
  • General
    • Special paint
    • US aid emblem
    • Miscellaneous inspection
    • EU Certificate of Conformance (CE)