SPECIFICATION SUMMARY
PRICE (USD)
Call 440-838-7348 for rate information
Engine Specifications
-
Bore6.69 in
-
Stroke (HD)8.46 in
-
AspirationTA
-
Fuel SystemElectronic unit injection
-
Engine Model3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
-
Stroke - Standard7.48 in
-
Compression Ratio14.7:1
-
Governor TypeAdem™3
-
AspirationTA
-
Fuel SystemElectronic unit injection
-
Bore6.69 in
-
Stroke - HD8.46 in
-
Fuel System7.48 in
Generator Set Specifications
-
Minimum Rating1650 ekW
-
Maximum Rating2500 ekW
-
Voltage220 to 13800 volts
-
Frequency60 Hz
-
Speed1800 rpm
-
Emissions/Fuel StrategyU.S. EPA Cert., Tier 2
Generator Set Dimensions
-
Height - Maximum118.5 in
-
Length - Maximum277 in
-
Width - Maximum101.2 in
Design Criteria
Cat Diesel Engine
Generator
EMCP Control Panel
Single-Source Supplier
World Wide Product Support
Seismic Certification
UL 2200 / CSA - Optional
Standard Equipment:
-
- Air Inlet System
-
- Air Cleaner; single element canister type
-
- Air Inlet
-
- Air Cleaner
-
- Control Panels
-
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
- Controls: Speed adjust - Auto / start / stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- Generator mounted - rear facing
- EMCP 4.2B
- Number of I/O varies on options selected: 4 programmable relay outputs (Form A) - 1 programmable relay outputs (Form C) - 1 programmable digital outputs
- Text alarm / event descriptions
- Emergency stop pushbutton
- Digital indication for: RPM - DC volts - Operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
- 24 Volt DC operation
- Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
- Programmable protective relaying functions: Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kW) (32) - Reverse Reactive Power (kVAr) (32RV) - Overcurrent (50/51)
- Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Cat Connect - 3 Analog inputs - 6 Customer programmable digital inputs
- Environmental sealed front face
-
- Cooling
-
- Package mounted radiator
-
- Exhaust
-
- Exhaust flange outlet
-
- Fuel
-
- Fuel priming pump
- Primary fuel filter with integral water separator
- Secondary fuel filter
-
- Generator
-
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
-
- Power Termination
-
- Bus Bar
-
- Cooling System
-
- ATAAC - 3516E Package radiators shipped installed
- Certified standard PGS provided
-
- Control Panel
-
- EMCP 4 Genset Controller
-
- Exhaust System
-
- Dry exhaust manifold
- Flanged faced outlet(s)
-
- Fuel System
-
- Secondary fuel filters
- Fuel cooler; not included with packages without radiator
- Fuel priming pump
- Flexible fuel lines - shipped loose
-
- General
-
- Right hand servicing
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
- SAE Standard rotation
- Paint - Caterpillar Yellow except rails and radiators gloss black
-
- Generator And Attachments
-
- 6 lead
- High Voltage:
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- Internal excitation
- Winding temperature detectors
- Bus bar connections, right side extension box, bottom cable entry
- Winding temperature detectors
- NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Medium Voltage:
- Permanent magne
- NEMA standard hole pattern
- Form wound
- NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Form wound
- Random wound
- Winding temperature detectors
- Busbar connections, top center mounted, top cable entry
- Low Voltage:
- 3 Phase brushless, salient pole
- Anti condensation space heater
- NEMA standard hole pattern
- Form wound
-
- Governing System
-
- ADEM A3
-
- Literature
-
- English
-
- Lubrication System
-
- Fumes disposal
- Oil filter, filler and dipstick
- Oil drain lines and valve
- Fumes disposal
- Lubricating oil
- Integral lube oil cool
- Gear type lube oil pump
-
- Mounting System
-
- Rails - engine / generator / radiator mounting
- Rubber anti-vibration mounts (shipped loose)
- Anti-vibration mounts (shipped loose)
-
- Starting System
-
- 45 Amp charging alternator
- 45 Amp charging alternator
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery and battery rack w/cables
Optional Equipment:
-
- Control System
-
- EMCP 4.3, EMCB 4.4
-
- Exhaust
-
- Exhaust mufflers
-
- Air Inlet System
-
- Dual element air cleaner
- Single element filter
-
- Generator
-
- Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
- Anti-condensation heater
- Oversize and premium generators
-
- Cooling System
-
- Optional installed ATAAC radiators
- Water level switch gauges
- Standard ambient ATAAC radiators
- Optional installed radiators
- Coolant
- Standard ambient radiators
-
- Power Termination
-
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
-
- Crankcase System
-
- Explosion relief valves
- Ventilation system
- No explosion relief valves
-
- Control Panels
-
- Digital I/O module
- Load share module
- Remote monitoring software
- EMCP (4.2) (4.3) (4.4)
- Generator temperature monitoring & protection
-
- Exhaust System
-
- Y-Adapters
- Tier 4 dosing cabinet
- Tier 4 clean emission MOD Kits
- Flanges
- Exhaust offset
- Flange and exhaust expanders
- Mufflers
- Clean emission parts
- Flexible fittings
- Tier 4 clean emissions module
- Elbows
-
- Mounting
-
- Spring-type vibration isolator
- IBC isolators
- Rubber anti-vibration mounts
-
- Fuel System
-
- Primary Fuel Filter
- Fuel Priming Pumps (Tier 4) - Manual or Electric
-
- Starting/charging
-
- Battery chargers
- Jacket water heater
- Air starting motor with control and silencer
- Charging alternator
- Oversize batteries
- Heavy-duty starting system
-
- General
-
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- US aid emblem
- Enclosures: sound attenuated, weather protective
- CSA Certification
- EEC Declaration of Conformity
- EU Certificate of Conformance (CE)
- The following options are based on regional and product configuration:
- UL 2200 package
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Integral & sub-base UL listed dual wall fuel tanks
- Integral & sub-base fuel tanks
- Automatic transfer switches (ATS)
-
- Generators And Attachments
-
- Thermostate for space heater
- Generator conversion
- Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Space heater kits
- Alternator air cleaner
- Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
- High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Differntial current transformers (DCT) 8.7 kV and 15 kV classes
- High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Differential current transformers (DCT)
-
- Instrumentation
-
- Pyrometer and thermocouples
-
- Lubrication System
-
- Prelube pumps
- Oil level regulator
- Lube oil in standard sump
-
- Mounting System
-
- IBC vibration isolators
- Puck style low efficiency isolators
- Spring type vibration isolators
-
- Power Connections
-
- Ground cables between generator and terminal box
- Neutral ground connections
- 2700 Frame, four lead, four terminal
- Left side power connections
- Right side power connections
- Rear power connections
- Low voltage circuit breakers
- Center post busbar
-
- Special Tests / Reports
-
- Fuel consumption test
- Standard engine test charge
- OSHPD certification
- PGS test report @ 0.8 power factor
- PGS test report @ 1.0 power factor
- IBC certification
- Generator set fuel consumption test
- Torsional vibration analysis reports
- Generator test report
- Canadian Standards Association certification
-
- Starting And Charging System
-
- Air pressure regulator
- Jacket water heaters
- Air starting motors
- Electric starting motors
- Starter cover
- Engine barring device
- 10, 20, 35 and 50 amp battery chargers
- 24 Volt battery set - Dry
-
- Extended Service Coverage
-
- Platinum, Gold and Silver coverage