ATC-300+ CONTROLLER

The ATC-300+ is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels. The ATC-300+ Controller provides programmed flexibility to address the needs of any system. It operates from all system voltages between 120 to 600V, single-phase and three-phase at 50 or 60 Hz. In addition, a period of no control power is provided. The controller monitors the condition of the three-phase line-to-line voltage and frequency of Source 1 and Source 2 power sources and can be programmed for single-phase operation. The ATC-300+ Controller provides the intelligence to ensure that the ATS operates properly through a series of programmed sensing and timing functions.

Videos not available for this product.

360 View not available for this product.

SPECIFICATION SUMMARY
  • Rating Range 120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type Switch application dependent
  • Switch Type Switch application dependent
  • Input Control Voltage 65 to 145 Vac 50/60 hZ

PRICE (USD)
Call 440-838-7348 for rate information

Technical Summary

  • Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent
  • Rating Range
    120 to 600V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent

ATC Controller Specifications

  • Input Control Voltage
    65 to 145 Vac 50/60 hZ
  • Voltage Measurements of Utility
    Source 1 VAB Source 2 VAB
    Source 1 VAC Source 2 VBC
    Source 1 VCA Source 2 VCA
  • Voltage Measurement Range
    0 to 790 VAC rms (50/60 Hz)
  • Voltage Measurement Accuracy
    +/-2% of nominal input voltage
  • Frequency Measurements Of
    Source 1 and Source 2
  • Frequency Measurement Range
    40 Hz to 70 Hz
  • Frequency Measurement Accuracy
    +/- 0.1 Hz
  • Undervoltage Dropout
    50% to 90% of nominal voltage
  • Undervoltage Pickup
    (Dropout +2%) to 99% of the nominal system voltage
  • Underfrequency Dropout Range
    90 to 97% of the nominal system frequency
  • Underfrequency Pickup Range
    (Dropout +1 Hz) to 99% of the nominal system frequency
  • Overfrequency Dropout Range
    103 to 110% of the nominal system frequency
  • Overfrequency Pickup Range
    101% to (dropout - 1 Hz) of the nominal system frequency
  • Operating Temperature Range
    -20 to 70 degree C (-4 to +158 degree F)
  • Storage Temperature Range
    -30 to 85 degree C (-22 to +185 degree F)
  • Operating Humidity
    0 to 95% relative humidity (noncondensing)
  • Operating Environment
    Resistant to ammonia, methane, nitrogen,hydrogen and hydrocarbons
  • Generator Start Relay
    5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load
  • K1, K2 Relays

    10A, 1-3 hp @ 250 Vac

    10A@30 Vdc
  • Applicable Testing
    UL-recognized component
    Meets intent of UL 991 & UL 1008
    Meets IEC 1000-4-2, 1000-4-3, 1000-4-4
  • Applicable Testing Continued
    1000-4-5, 1000-4-6, 1000-4-11
    CISPR 11, Class A
    FCC Part 15, Class A
    CSS 22.2-178
  • Enclosure Compatibility
    NEMA 1, NEMA 3R and NEMA 12
    UV-resistant ATC-300+ faceplate

Product Features

  • Auxiliary relay contacts:
    • Source 1 present 2NO and 2NC
    • Source 2 present 2NO and 2NC
  • Source 1 and source 2 sensing:
    • Undervoltage / underfrequency
    • Overvoltage / overfrequency
    • Three-phase rotation protection
    • Three-phase voltage unbalance/loss
  • Pre-transfer signal contacts 1NO and 1NC
  • Go to emergency (Source 2)
  • Seven field-programmable time delays
  • LCD-based display for programming, system diagnostic and help message display
  • Mimic diagram with source available and connected LED indication
  • Time-stamped history log
  • System test pushbutton
  • Programmable plant exercise (off, daily, 7,14 and 28 day) interval selectable run time 0-600 minutes no load/load with fail-safe
  • Integral overcurrent protection (optional)
  • In-phase transition
  • Stainless steel cover for controller (optional)
  • Communications via RS-232 or Modbus through an integrated RS-485 port (optional)